AT Commands reference

AT commands are useful to communicate with the device from third party peripherals. A good use case is implememting a HMI using ESPHome and LVGL which not only offers a nice touch screen interface, but offers another way to integrate the EVSE with Home Assistant.

AT commands support can be enabled in serial settings, any serial interface can be used for this.

Note

Only one interface can work in AT commands mode.

Basic commands~

When AT Commands module is enabled, at startup, the device will print automatically on the line the RDY message once, to inform the client that communication can start. Since this mostly happens when the board booted up, it can be useful to detect on the client side a freshly booted state.

AT~

Check that the communication is working properly.

Command Return Value Return Code
AT - OK

ATE~

Echo back to the client the AT command input (see the entered commands on a serial console terminal).

Command Return Value Return Code
ATE<echo> - OK
Parameter Access Type Description
<echo> WO uint8 Echo commands (0 or 1)

AT+CMD~

List all the supported AT commands by the ESP32-EVSE device.

Command Return Value Return Code
AT+CMD List of commands OK

Example:

AT+CMD

ATE0

ATE1

AT+RST

AT+CHIP?
AT+CHIP=?

AT+HEAP?
AT+HEAP=?

  ...

OK

AT+SUB~

Subscribe to periodic response to other commands, let ESP32-EVSE send responses automatically, repeatedly.

Command Return Value Return Code
AT+SUB=<command>,<period> - OK | ERROR
AT+SUB=? Command description OK
Parameter Access Type Description
<command> W string AT command name (max length 32)
<period> W uint32 Time period in ms

Example:

AT+SUB="+ENABLE",1000
OK
AT+SUB="+AVAILABLE",2000
OK
+ENABLE=1
+ENABLE=1
+AVAILABLE=1
+ENABLE=1
+ENABLE=1
+AVAILABLE=1

Note

Only works with read commands (not write, test or execute). When you subscribe multiple times to the same command, only the period will be updated. AT commands task run in a 100ms delay loop, setting any period of lower value has no effect.

AT+UNSUB~

Unsubscribe periodical reading of a certain command.

Command Return Value Return Code
AT+UNSUB=<command> - OK
AT+UNSUB=? Command description OK
Parameter Access Type Description
<command> W string AT command name (max length 32)

Example:

AT+SUB="+ENABLE",1000
OK
AT+SUB="+AVAILABLE",1000
OK
+ENABLE=1
+AVAILABLE=1
+ENABLE=1
+AVAILABLE=1
AT+UNSUB="+ENABLE"
+AVAILABLE=1
+AVAILABLE=1

AT+SUB="+ENABLE",1000
OK
AT+SUB="+AVAILABLE",1000
OK
+ENABLE=1
+AVAILABLE=1
AT+UNSUB=""

Note

Call with empty string removes all command subscriptions.

System commands~

AT+RST~

Restart ESP32-EVSE device.

Command Return Value Return Code
AT+RST - OK

AT+UPTIME~

Print time since last boot, in seconds.

Command Return Value Return Code
AT+UPTIME? +UPTIME=<uptime> OK
AT+UPTIME=? Command description OK
Parameter Access Type Description
<time> RW uint32 Time in s

AT+CHIP~

Print ESP32 chip model information.

Command Return Value Return Code
AT+CHIP? +CHIP=<model>,<cores>,<revision> OK
AT+CHIP=? Command description OK
Parameter Access Type Description
<model> RO string Name of model
<cores> RO uint8 Number of CPU cores
<revision> RO uint16 Chip revision number (in format MXX; where M - wafer major version, XX - wafer minor version)

Example:

AT+CHIP?
+CHIP="esp32",2,100
OK

AT+HEAP~

Print memory heap status.

Command Return Value Return Code
AT+HEAP? +HEAP=<used>,<total> OK
AT+HEAP=? Command description OK
Parameter Access Type Description
<used> RO uint32 Used heap size in bytes
<total> RO uint32 Total heap size in bytes

Example:

AT+HEAP?
+HEAP=115992,308884
OK

AT+VER~

Print ESP32-EVSE firmware version.

Command Return Value Return Code
AT+VER? +VER=<version> OK
AT+VER=? Command description OK
Parameter Access Type Description
<version> RO string Version, commonly in format major.minor.bugfix

Example:

AT+VER?
+VER="v2.0.0"
OK

AT+IDFVER~

Print ESP-IDF version that was used to build the firmware.

Command Return Value Return Code
AT+IDFVER? +IDFVER=<version> OK
AT+IDFVER=? Command description OK
Parameter Access Type Description
<version> RO string ESP-IDF version

Example:

AT+IDFVER?
+IDFVER="v5.5"
OK

AT+BUILDTIME~

Print the datetime of build.

Command Return Value Return Code
AT+BUILDTIME? +BUILDTIME=<date>,<time> OK
AT+BUILDTIME=? Command description OK
Parameter Access Type Description
<date> RO string Compile date
<time> RO string Compile time

Example:

AT+BUILDTIME?
+BUILDTIME="Aug 20 2025","22:13:07"
OK

AT+TEMP~

Print the measured temperature values.

Command Return Value Return Code
AT+TEMP? +TEMP=<count>,<high>,<low> OK
AT+TEMP=? Command description OK
Parameter Access Type Description
<count> RO uint8 Count of temperature sensors
<high> RO int32 Highest temperature in dg.C*100
<low> RO int32 Lowest temperature in dg.C*100

Example:

AT+TEMP?
+TEMP=2,2965,2887
OK

AT+TEMP?
+TEMP=1,2875,2875
OK

AT+TEMP?
+TEMP=0,0,0
OK

Note

In the example above: first reading has 2 temperature sensors; second reading has 1 temperature sensor; last reading has no temperature sensor.

AT+TZ~

Read/write timezone name.

Command Return Value Return Code
AT+TZ? +TZ=<timezone> OK
AT+TZ=<timezone> - OK | ERROR
AT+TZ=? Command description OK
Parameter Access Type Description
<timezone> RW string Timezone name (max length 32)

Example:

AT+TZ?
+TZ="Etc/UTC"
OK

AT+TZ="Europe/Prague"
OK

AT+TZRULE~

Read Posix timezone string.

Command Return Value Return Code
AT+TZRULE? +TZRULE=<timezone_rule> OK
AT+TZRULE=? Command description OK
Parameter Access Type Description
<timezone_rule> RO string Posix timezone string (max length 32)

Example:

AT+TZRULE?
+TZRULE="CET-1CEST,M3.5.0,M10.5.0/3"
OK

AT+TIME~

Read/write epoch Unix timestamp (write to set the system time manually).

Command Return Value Return Code
AT+TIME? +TIME=<time> OK
AT+TIME=<time> - OK
AT+TIME=? Command description OK
Parameter Access Type Description
<time> RW uint64 Epoch time in s

Example:

AT+TIME?
+TIME=1756129834
OK

EVSE commands~

AT+STATE~

Print ESP32-EVSE internal state according to J1772 standard.

Command Return Value Return Code
AT+STATE? +STATE=<state> OK
AT+STATE=? Command description OK
Parameter Access Type Description
<state> RO uint8 IEC 61851 / J1772 state: A=0, B1=1, B2=2, C1=3, C2=4, D1=5, D2=6, E=7, F=8. See State machine

Example:

AT+STATE?
+STATE=4
OK

AT+ERROR~

Print ESP32-EVSE error bits in decimal value (use bitmask to decode).

Command Return Value Return Code
AT+ERROR? +ERROR=<error> OK
AT+ERROR=? Command description OK
Parameter Access Type Description
<error> RO uint32 EVSE error bit

Example:

AT+ERROR?
+ERROR=0
OK

AT+ENABLE~

Read/write ESP32-EVSE charging enabled setting.

Command Return Value Return Code
AT+ENABLE? +ENABLE=<enable> OK
AT+ENABLE=<enable> - OK
AT+ENABLE=? Command description OK
Parameter Access Type Description
<enable> RW uint8 Charger enabled (0 or 1)

Example:

AT+ENABLE?
+ENABLE=0
OK

AT+ENABLE=1
OK

AT+AVAILABLE~

Read/write ESP32-EVSE charging available setting (F state).

Command Return Value Return Code
AT+AVAILABLE? +AVAILABLE=<available> OK
AT+AVAILABLE=<available> - OK
AT+AVAILABLE=? Command description OK
Parameter Access Type Description
<available> RW uint8 Charger available (0 or 1)

Example:

AT+AVAILABLE?
+AVAILABLE=0
OK

Note

When ESP32-EVSE is set to be available=0 it doesn't mean that state will always be F. Error can override the state to E.

AT+REQAUTH~

Read/write ESP32-EVSE require authorization option before starting to charge.

Command Return Value Return Code
AT+REQAUTH? +REQAUTH=<require_auth> OK
AT+REQAUTH=<require_auth> - OK
AT+REQAUTH=? Command description OK
Parameter Access Type Description
<require_auth> RW uint8 Authorization required (0 or 1)

Example:

AT+REQAUTH?
+REQAUTH=0
OK

AT+PENDAUTH~

Print the state of the ESP32-EVSE pending authorization bit.

Command Return Value Return Code
AT+PENDAUTH? +PENDAUTH=<pending_auth> OK
AT+PENDAUTH=? Command description OK
Parameter Access Type Description
<pending_auth> RO uint8 Authorization pending (0 or 1)

Example:

AT+PENDAUTH?
+PENDAUTH=1
OK

AT+AUTH~

This command is to confirm the pending authorization, and allow the system to charge.

Command Return Value Return Code
AT+AUTH --- OK

Example:

AT+AUTH
OK

AT+CHCUR~

Read/write the actual charging current value. Value must be in range 6A - MAXCHCUR.

Command Return Value Return Code
AT+CHCUR? +CHCUR=<current> OK
AT+CHCUR=<current> - OK | ERROR
AT+CHCUR=? Command description OK
Parameter Access Type Description
<current> RW uint16 Charging current in A*10

Example:

AT+CHCUR?
+CHCUR=60
OK

AT+CHCUR=20
ERROR

Note

The example above returns error because value 2A is out of range (6A is lower limit)

AT+DEFCHCUR~

Read/write default charging current. Value must be in range 6A - MAXCHCUR.

Command Return Value Return Code
AT+DEFCHCUR? +DEFCHCUR=<current> OK
AT+DEFCHCUR=<current> - OK | ERROR
AT+DEFCHCUR=? Command description OK
Parameter Access Type Description
<current> RW uint16 Charging current in A*10

Example:

AT+DEFCHCUR?
+DEFCHCUR=320
OK

AT+MAXCHCUR~

Read/write max charging current. Value must be in range 6A - 63A.

Command Return Value Return Code
AT+MAXCHCUR? +MAXCHCUR=<current> OK
AT+MAXCHCUR=<current> - OK | ERROR
AT+MAXCHCUR=? Command description OK
Parameter Access Type Description
<current> RW uint8 Charging current in A

Example:

AT+MAXCHCUR?
+MAXCHCUR=63
OK

Note

Set this to match the electrical limits of your installation!

AT+CONSUMLIM~

Read/write energy consumption limit (stop charging session if the limit has been hit).

Command Return Value Return Code
AT+CONSUMLIM? +CONSUMLIM=<consumption> OK
AT+CONSUMLIM=<consumption> - OK
AT+CONSUMLIM=? Command description OK
Parameter Access Type Description
<consumption> RW uint32 Consumption in Wh

Example:

AT+CONSUMLIM?
+CONSUMLIM=0
OK

Note

Value 0 means no limit

AT+DEFCONSUMLIM~

Read/write the default consumption limit.

Command Return Value Return Code
AT+DEFCONSUMLIM? +DEFCONSUMLIM=<consumption> OK
AT+DEFCONSUMLIM=<consumption> - OK
AT+DEFCONSUMLIM=? Command description OK
Parameter Access Type Description
<consumption> RW uint32 Consumption in Wh

Example:

AT+DEFCONSUMLIM?
+DEFCONSUMLIM=25000
OK

Note

This example sets a 25 kWh amount of energy consumption limit

Note

Value 0 means no limit

AT+CHTIMELIM~

Read/write charging time limit (stop charging session if the limit has been hit).

Command Return Value Return Code
AT+CHTIMELIM? +CHTIMELIM=<time> OK
AT+CHTIMELIM=<time> - OK
AT+CHTIMELIM=? Command description OK
Parameter Access Type Description
<time> RW uint32 Time in s

Example:

AT+CHTIMELIM=7200
OK

Note

This example sets a 2h charging time limit

Note

Value 0 means no limit

AT+DEFCHTIMELIM~

Read/write the default charging time limit.

Command Return Value Return Code
AT+DEFCHTIMELIM? +DEFCHTIMELIM=<time> OK
AT+DEFCHTIMELIM=<time> - OK
AT+DEFCHTIMELIM=? Command description OK
Parameter Access Type Description
<time> RW uint32 Time in s

Example:

AT+DEFCHTIMELIM?
+DEFCHTIMELIM=0
OK

Note

Value 0 means no limit

AT+UNDERPOWERLIM~

Read/write under power charging limit (stop charging session when power falls under the limit).

Command Return Value Return Code
AT+UNDERPOWERLIM? +UNDERPOWERLIM=<power> OK
AT+UNDERPOWERLIM=<power> - OK
AT+UNDERPOWERLIM=? Command description OK
Parameter Access Type Description
<power> RW uint16 Power in W

Example:

AT+UNDERPOWERLIM?
+UNDERPOWERLIM=0
OK

Note

Value 0 means no limit

AT+DEFUNDERPOWERLIM~

Read/write the default under power charging limit.

Command Return Value Return Code
AT+DEFUNDERPOWERLIM? +DEFUNDERPOWERLIM=<power> OK
AT+DEFUNDERPOWERLIM=<power> - OK
AT+DEFUNDERPOWERLIM=? Command description OK
Parameter Access Type Description
<power> RW uint16 Power in W

Example:

AT+DEFUNDERPOWERLIM?
+DEFUNDERPOWERLIM=0
OK

Note

Value 0 means no limit

AT+LIMREACH~

Print the state of the charging limit bit (any limit was reached).

Command Return Value Return Code
AT+LIMREACH? +LIMREACH=<reached> OK
AT+LIMREACH=? Command description OK
Parameter Access Type Description
<reached> R uint8 Is charging limit reached (0 or 1)

Example:

AT+LIMREACH?
+LIMREACH=0
OK

AT+SOCKETOUTLET~

Read/write socket outlet installation setting. Set it only for PP board. This enables detection of provided cable max current, and socket lock functionality (if it's available).

Command Return Value Return Code
AT+SOCKETOUTLET? +SOCKETOUTLET=<socket_outlet> OK
AT+SOCKETOUTLET=<socket_outlet> - OK | ERROR
AT+SOCKETOUTLET=? Command description OK
Parameter Access Type Description
<socket_outlet> RW uint8 Socket outlet (0 or 1)

Example:

AT+SOCKETOUTLET?
+SOCKETOUTLET=0
OK

Note

Value 0 means no limit

Energy meter commands~

AT+EMETERMODE~

Read/write energy meter mode. Value CUR require EMETER=(2|1),x. Value CUR_VLT require EMETER=2,x.

Command Return Value Return Code
AT+EMETERMODE? +EMETERMODE=<mode> OK
AT+EMETERMODE=<mode> - OK | ERROR
AT+EMETERMODE=? Command description OK
Parameter Access Type Description
<mode> RW uint8 Mode number (DUMMY=0, CUR=1, CUR_VLT=2)

Example:

AT+EMETERMODE?
+EMETERMODE=1
OK

AT+EMETERMODE=5
ERROR

Note

In the example above, value 5 fails because it is out of range

AT+EMETERACVOLTAGE~

Read/write energy meter voltage setting, used for calculation in DUMMY and CUR mode (use range 100V - 300V).

Command Return Value Return Code
AT+EMETERACVOLTAGE? +EMETERACVOLTAGE=<voltage> OK
AT+EMETERACVOLTAGE=<voltage> - OK | ERROR
AT+EMETERACVOLTAGE=? Command description OK
Parameter Access Type Description
<voltage> RW uint16 Voltage in V

Example:

AT+EMETERACVOLTAGE?
+EMETERACVOLTAGE=253
OK

AT+EMETERACVOLTAGE=305
ERROR

Note

In the example above, setting value 305 fails because it is out of range

AT+EMETERTHREEPHASE~

Read/write energy meter three phase mode setting.

Command Return Value Return Code
AT+EMETERTHREEPHASE? +EMETERTHREEPHASE=<three_phases> OK
AT+EMETERTHREEPHASE=<three_phases> - OK
AT+EMETERTHREEPHASE=? Command description OK
Parameter Access Type Description
<three_phases> RW uint8 Three phases (0 or 1)

Example:

AT+EMETERTHREEPHASE?
+EMETERTHREEPHASE=1
OK

AT+EMETERPOWER~

Print the value of the actual charging power.

Command Return Value Return Code
AT+EMETERPOWER? +EMETERPOWER=<power> OK
AT+EMETERPOWER=? Command description OK
Parameter Access Type Description
<power> RO uint16 Power in W

Example:

AT+EMETERPOWER?
+EMETERPOWER=11085
OK

AT+EMETERSESTIME~

Print the duration of the current charging session.

Command Return Value Return Code
AT+EMETERSESTIME? +EMETERSESTIME=<time> OK
AT+EMETERSESTIME=? Command description OK
Parameter Access Type Description
<time> RO uint32 Time in s

Example:

AT+EMETERSESTIME?
+EMETERSESTIME=3769
OK

AT+EMETERCHTIME~

Print the amount of time spent with charging.

Command Return Value Return Code
AT+EMETERCHTIME? +EMETERCHTIME=<time> OK
AT+EMETERCHTIME=? Command description OK
Parameter Access Type Description
<time> RO uint32 Time in s

Example:

AT+EMETERCHTIME?
+EMETERCHTIME=3702
OK

AT+EMETERCONSUM~

Print the energy consumption of the actual session.

Command Return Value Return Code
AT+EMETERCONSUM? +EMETERCONSUM=<consumption> OK
AT+EMETERCONSUM=? Command description OK
Parameter Access Type Description
<consumption> RO uint32 Consumption in Wh

Example:

AT+EMETERCONSUM?
+EMETERCONSUM=35547
OK

AT+EMETERTOTCONSUM~

Read/reset the total energy delivered with this ESP32-EVSE device.

Command Return Value Return Code
AT+EMETERTOTCONSUM? +EMETERTOTCONSUM=<consumption> OK
AT+EMETERTOTCONSUM=<consumption> - OK | ERROR
AT+EMETERTOTCONSUM=? Command description OK
Parameter Access Type Description
<consumption> RW uint64 Consumption in Wh

Example:

AT+EMETERTOTCONSUM?
+EMETERTOTCONSUM=915517547
OK

AT+EMETERCONSUM=0
OK

AT+EMETERCONSUM=5
ERROR

Note

To reset total consumption use value 0, other values will throw an error.

AT+EMETERVOLTAGE~

Print the measured or preset voltage.

Command Return Value Return Code
AT+EMETERVOLTAGE? +EMETERVOLTAGE=<l1_vlt>,<l2_vlt>,<l3_vlt> OK
AT+EMETERVOLTAGE=? Command description OK
Parameter Access Type Description
<l1_vlt> RO uint32 L1 voltage in mV
<l2_vlt> RO uint32 L2 voltage in mV
<l3_vlt> RO uint32 L3 voltage in mV

Example:

AT+EMETERVOLTAGE?
+EMETERVOLTAGE=255951,254753,255852
OK

AT+EMETERVOLTAGE?
+EMETERVOLTAGE=250000,0,0
OK

Note

When energy meter is single phase, L2 and L3 voltage are 0.

AT+EMETERCURRENT~

Print the measured or preset current.

Command Return Value Return Code
AT+EMETERCURRENT? +EMETERCURRENT=<l1_cur>,<l2_cur>,<l3_cur> OK
AT+EMETERCURRENT=? Command description OK
Parameter Access Type Description
<l1_cur> RO uint32 L1 current in mA
<l2_cur> RO uint32 L2 current in mA
<l3_cur> RO uint32 L3 current in mA

Example:

AT+EMETERCURRENT?
+EMETERCURRENT=10951,10753,105852
OK

AT+EMETERCURRENT?
+EMETERCURRENT=32000,0,0
OK

Note

When energy meter is single phase, L2 and L3 current are 0.

Network commands~

AT+WIFISTACFG~

This command is used to read/write WiFi STA (client) configuration.

Command Return Value Return Code
AT+WIFISTACFG? +WIFISTACFG=<enabled>,<ssid>,<password> OK
AT+WIFISTACFG=<enabled>,<ssid>,<password> - OK | ERROR
AT+WIFISTACFG=? Command description OK
Parameter Access Type Description
<enabled> RW uint8 Enabled/disable STA (0 or 1)
<ssid> RW string SSID (max length 32)
<password> WO string Password (max length 32)

Example:

AT+WIFISTACFG?
+WIFISTACFG=1,"MirkoTik-E12345",""
OK

AT+WIFISTACFG=0
OK

AT+WIFISTACFG?
+WIFISTACFG=0,"MirkoTik-E12345",""
OK

AT+WIFISTACFG=1,"MirkoTik-E99999","topsecret"
OK

AT+WIFISTACFG?
+WIFISTACFG=1,"MirkoTik-E99999",""
OK

Note

Calling WIFISTACFG=(0|1) only disables/enables the WiFi client, SSID and password will be not modified.

AT+WIFIAPCFG~

Read/write WiFi access point mode configuration.

Command Return Value Return Code
AT+WIFIAPCFG? +WIFIAPCFG=<enabled>,<ssid> OK
AT+WIFIAPCFG=<enabled> - OK
AT+WIFIAPCFG=? Command description OK
Parameter Access Type Description
<enabled> RW uint8 Enabled/disable AP (0 or 1)
<ssid> RO string SSID (max length 32)

Example:

AT+WIFIAPCFG?
+WIFIAPCFG=0,"ESP32-EVSE-03fc60"
OK

AT+WIFIAPCFG=1
OK

AT+WIFISTACFG?
+WIFIAPCFG=1,"ESP32-EVSE-03fb59"
OK

Note

After enabling access point mode, if there's no client connected within 1 minute, access point mode will be disabled.

AT+WIFISTACONN~

Print WiFi client mode connection state.

Command Return Value Return Code
AT+WIFISTACONN? +WIFISTACONN=<connection>,<rssi> OK
AT+WIFISTACONN=? Command description OK
Parameter Access Type Description
<connection> RO uint8 Has connection (0 or 1)
<rssi> RO int8 RSSI in dB

Example:

AT+WIFISTACONN?
+WIFISTACONN=1,-61
OK

AT+WIFIAPCONN~

Print WiFi access point mode connection state.

Command Return Value Return Code
AT+WIFIAPCONN? +WIFIAPCONN=<connection> OK
AT+WIFIAPCONN=? Command description OK
Parameter Access Type Description
<connection> RO uint8 Has connection (0 or 1)

Example:

AT+WIFIAPCONN?
+WIFIAPCONN=0
OK

AT+WIFISTASTATIC~

This command is used to read/write WiFi STA static IP configuration.

Command Return Value Return Code
AT+WIFISTASTATIC? +WIFISTASTATIC=<enabled>,<ip>,<gateway>,<netmask>,<dns> OK
AT+WIFISTASTATIC=<enabled>,<ip>,<gateway>,<netmask><dns> - OK | ERROR
AT+WIFISTASTATIC=? Command description OK
Parameter Access Type Description
<enabled> RW uint8 Enabled/disable static IP (0 or 1)
<ip> RW string IP address (max length 32)
<gateway> RW string Gateway (max length 32)
<netmask> RW string Netmask (max length 32)
<dns> RW string DNS server (max length 32)

Example:

OK
AT+WIFISTASTATIC?
+WIFISTASTATIC=1,"192.168.88.100","192.168.88.1","255.255.255.0","192.168.88.1"
OK

AT+WIFISTASTATIC=0
OK

AT+WIFISTASTATIC?
+WIFISTASTATIC=0,"192.168.88.100","192.168.88.1","255.255.255.0","192.168.88.1"
OK

AT+WIFISTASTATIC=1,"192.168.88.101"
OK

Note

Calling WIFISTASTATIC=(0|1) only disables/enables the static IP, other parameters will be not modified.

AT+WIFISTAIP~

Print WiFi client IP address.

Command Return Value Return Code
AT+WIFISTAIP? +WIFISTAIP=<ip> OK
AT+WIFISTAIP=? Command description OK
Parameter Access Type Description
<ip> RO string IP address

Example:

AT+WIFISTAIP?
+WIFISTAIP="192.168.88.50"
OK

AT+WIFISTAMAC~

Print WiFi client MAC address.

Command Return Value Return Code
AT+WIFISTAMAC? +WIFISTAMAC=<mac> OK
AT+WIFISTAMAC=? Command description OK
Parameter Access Type Description
<mac> RO string IP address

Example:

AT+WIFISTAMAC?
+WIFISTAMAC="30:c6:f7:x3:ab:5c"
OK

AT+WIFIAPIP~

Print WiFi access point IP address.

Command Return Value Return Code
AT+WIFIAPIP? +WIFIAPIP=<ip> OK
AT+WIFIAPIP=? Command description OK
Parameter Access Type Description
<ip> RO string IP address

Example:

AT+WIFIAPIP?
+WIFIAPIP="192.168.4.1"
OK

AT+WIFIAPMAC~

Print WiFi access point MAC address.

Command Return Value Return Code
AT+WIFIAPMAC? +WIFIAPMAC=<mac> OK
AT+WIFIAPMAC=? Command description OK
Parameter Access Type Description
<mac> RO string IP address

Example:

AT+WIFIAPMAC?
+WIFIAPMAC="30:c6:f7:x3:ab:5d"
OK

AT+WIFIAPSCAN~

Scan WiFi for surrounding acc esspoints.

Command Return Value Return Code
AT+WIFIAPSCAN +WIFIAPSCAN=<ssid>,<auth>,<rssi> OK
Parameter Access Type Description
<ssid> RO string AP SSID (max length 32)
<auth> RO uint8 AP require authentication (0 or 1)
<rssi> RO int8 AP RSSI in dB

Example:

AT+WIFIAPSCAN
+WIFIAPSCAN="MirkoTik-E12345",1,-51
+WIFIAPSCAN="Pretty fly for a WiFi",1,-69
+WIFIAPSCAN="Winternet is Coming",1,-72
+WIFIAPSCAN="The LAN Before Time",1,-75
OK

AT+HOSTNAME~

Read/write mDNS hostname.

Command Return Value Return Code
AT+HOSTNAME? +HOSTNAME=<hostname> OK
AT+HOSTNAME=<hostname> - OK | ERROR
AT+HOSTNAME=? Command description OK
Parameter Access Type Description
<hostname> RO string Hostname (max length 32)

Example:

AT+HOSTNAME?
+HOSTNAME="evse"
OK

AT+HOSTNAME="evse2"
OK

AT+INSTNAME~

Read/write mDNS instance name.

Command Return Value Return Code
AT+INSTNAME? +INSTNAME=<instance_name> OK
AT+INSTNAME=<instance_name> - OK | ERROR
AT+INSTNAME=? Command description OK
Parameter Access Type Description
<instance_name> RO string Instance name (max length 32)

Example:

AT+INSTNAME?
+INSTNAME="evse"
OK

AT+INSTNAME="evse2"
OK

Serial commands~

AT+SERIAL~

Read/write serial configuration.

Command Return Value Return Code
AT+SERIAL<id>? +SERIAL<id>=<mode>,<baud_rate>,<data_bits>,<stop_bits>,<parity> OK
AT+SERIAL<id>=<mode>,<baud_rate>,<data_bits>,<stop_bits>,<parity> - OK
AT+SERIAL<id>=? Command description OK
Parameter Access Type Description
<id> RW uint8 Serial id (0,1,2?, some chips has only 2 uart)
<mode> RW uint8 Serial mode (NONE=0, LOG=1, MODBUS=2, NEXTION=3, SCRIPT=4, AT=5)
<baud_rate> RW uint32 Serial baud rate
<data_bits> RW uint8 Serial data bits (enum values uart_word_length_t)
<stop_bits> RW uint8 Serial stop bits (enum values uart_stop_bits_t)
<parity> RW uint8 Serial parity (enum values uart_parity_t)

Example:

AT+SERIAL0?
+SERIAL0=0,115200,3,1,0
OK

Note

Remember which serial port you are using for AT commands. After changing the currently used serial port, you will not be able to revert the changes from here.

Board config~

The commands below provide functionality to read board config.

AT+DEVNAME~

Print device name.

Command Return Value Return Code
AT+DEVNAME? +DEVNAME=<device_name> OK
AT+DEVNAME=? Command description OK
Parameter Access Type Description
<device_name> RO string Device name (max length 32)

Example:

AT+DEVNAME?
+DEVNAME="ESP32-DevKitC EVSE"
OK

AT+SOCKETLOCK~

Print the definition of socket lock.

Command Return Value Return Code
AT+SOCKETLOCK? +SOCKETLOCK=<socket_lock> OK
AT+SOCKETLOCK=? Command description OK
Parameter Access Type Description
<socket_lock> RO uint8 Has defined socket lock (0 or 1)

Example:

AT+SOCKETLOCK?
+SOCKETLOCK=1
OK

AT+SOCKETLOCKMINBREAKTIME~

Print socket lock minimum break time.

Command Return Value Return Code
AT+SOCKETLOCKMINBREAKTIME? +SOCKETLOCKMINBREAKTIME=<min_break_time> OK
AT+SOCKETLOCKMINBREAKTIME=? Command description OK
Parameter Access Type Description
<min_break_time> RO uint16 Socket lock min break time in ms

Example:

AT+SOCKETLOCKMINBREAKTIME?
+SOCKETLOCKMINBREAKTIME=1
OK

AT+PROXIMITY~

Print the definition of a proximity pilot.

Command Return Value Return Code
AT+PROXIMITY? +PROXIMITY=<proximity> OK
AT+PROXIMITY=? Command description OK
Parameter Access Type Description
<proximity> RO uint8 Has defined proximity pilot (0 or 1)

Example:

AT+PROXIMITY?
+PROXIMITY=1
OK

AT+TEMPSENSOR~

Print the definition of a temperature sensor bus.

Command Return Value Return Code
AT+TEMPSENSOR? +TEMPSENSOR=<temperature_sensor> OK
AT+TEMPSENSOR=? Command description OK
Parameter Access Type Description
<temperature_sensor> RO uint8 Has defined temperature sensor bus (0 or 1)

Example:

AT+TEMPSENSOR?
+TEMPSENSOR=1
OK

Note

When you have defined temperature sensor bus, it doesn't automaticaly mean you have a connected temperature sensor. Command AT+TEMP returns the count of the active temperature sensors.

AT+EMETER~

Print the energy meter settings.

Command Return Value Return Code
AT+EMETER? +EMETER=<type>,<three_phases> OK
AT+EMETER=? Command description OK
Parameter Access Type Description
<type> RO uint8 Type of energy meter (NONE=0, CURRENT=1, CURRENT_VOLTAGE=2)
<three_phases> RO uint8 Three phases energy meter (0 or 1)

Example:

AT+TEMPSENSOR?
+EMETER=2,0
OK

AT+SERIALS~

Print the serial definitions.

Command Return Value Return Code
AT+SERIALS? +SERIALS=<type>,<name> OK
AT+SERIALS=? Command description OK
Parameter Access Type Description
<type> RO uint8 Type of serial (UART=1, RS485=2)
<name> RO string Name of serial (max length 32)

Example:

AT+SERIALS?
+SERIALS=1,"UART via USB"
+SERIALS=2,"RS485"
+SERIALS=1,"UART"
OK

AT+AUXINPUTS~

Print AUX input definitions.

Command Return Value Return Code
AT+AUXINPUTS? +AUXINPUTS=<name> OK
AT+AUXINPUTS=? Command description OK
Parameter Access Type Description
<name> RO string Name of input (max length 8)

Example:

AT+AUXINPUTS?
+AUXINPUTS="IN1"
+AUXINPUTS="IN2"
OK

AT+AUXOUTPUTS~

Print AUX output definitions.

Command Return Value Return Code
AT+AUXOUTPUTS? +AUXOUTPUTS=<name> OK
AT+AUXOUTPUTS=? Command description OK
Parameter Access Type Description
<name> RO string Name of output (max length 8)

Example:

AT+AUXOUTPUTS?
+AUXOUTPUTS="OUT1"
+AUXOUTPUTS="OUT2"
+AUXOUTPUTS="OUT3"
+AUXOUTPUTS="OUT4"
OK

AT+AUXANALOGINPUTS~

Print AUX analog input definitions.

Command Return Value Return Code
AT+AUXANALOGINPUTS? +AUXANALOGINPUTS=<name> OK
AT+AUXANALOGINPUTS=? Command description OK
Parameter Access Type Description
<name> RO string Name of analog input (max length 8)

Example:

AT+AUXANALOGINPUTS?
+AUXANALOGINPUTS="IN3"
OK

See also~